Specifications – Badger Meter Vortex Meters User Manual

Page 25

Advertising
background image

25

09-VRX-UM-00408 07/12

SPECIFICATIONS

MEASURED

Liquids

MINIMUM PIPE SIZE

4 inches (102 mm)

FLOW RATE MEASURED

2...18 fps (0.6...5.5 mps)

PROCESS TEMPERATURE

-20° F...300° F (-28° C...148° C)

PROCESS PRESSURE

-5...250 PSIG (-0.3...17 BARg)

MINIMUM BACK PRESSURE

See Figure 2 - BACK PRESSURE CALCULATIONS

MAXIMUM VISCOSITY

10 centistokes - Consult factory for higher viscosities

ACCURACY

±2.0% of reading

REPEATABILITY

±0.5% of reading

RESPONSE TIME

1 second

INPUT POWER

4-20 mA 2 Wire Current Loop Powered; +10 to +30 VDC, 25 mA max

ANALOG OUTPUT

4-20 mA Current Loop

Resolution 1:4000

Transient

Over-voltage: Category 3, in accordance with IEC 664

PULSE OUTPUT

Outputs one pulse for each increment of totalizers least signifi cant digit

Pulse Type:

Opto-Isolated open collector transistor

Maximum Voltage:

30 VDC

Pulse

Width

ON State:

20 ms / Max pulse rate 25 Hz

Current

ON State:

0.9 V drop @ 5.0 mA

or 0.7 V drop @ 0.1 mA

PROCESS CONNECTION

Stainless steel w/PPS transducer assembly
Standard: 2” ANSI 150 lb fl ange
Optional: 300 lb fl ange or ¾ NPT x 2 NPT Bushings

ENVIRONMENTAL

Ambient Temperature:

-20 °F to 110 °F (-30 °C to 43 °C)

Humidity: 0-90%

Non-condensing

DISPLAY

Flow Rate and Total
8 digit, .75” high numeric display; 8 character, .38” high alphanumeric
4-20 mA Loop Powered; +10 to +30 VDC, 25 mA max

ENCLOSURE

NEMA 4X (IP66) Polycarbonate