History Icon

The History icon indicates there is dispense result information that has not been

communicated to the keypad to complete a work order.
To send the dispense result information to the keypad, press the RESET button to initiate

communication.

Error Codes

The meter has several Error Codes that may display. These provide indication, at the meter, that there is an error in

communication between the meter and keypad.

F01

The meter radio is not working.
To clear the error, press the RESET button on the meter.

F02

The meter is not configured to a keypad.
To clear the error code, press the RESET button on the meter.
Verify that the meter radio address is configured properly.

F03

System busy.
To clear the error, press the RESET button on the meter.

F08

Meter lost connection to network.
Out of range—network connection lost.
Keypad not powered.
Meter moved out of range of keypad.

F09

Meter not connected to a network.
First time being powered up.
Network selected is not available.

SF0

(Scale Factor 0)

The Scale Factor setting for the meter is set to 0.000.
To input a valid Scale Factor for the meter follow the instructions in the Change Factory Settings section

of this manual.

All other

Error Codes

Are for factory purposes only.
To clear the meter, press RESET.