Operation, Meter buttons, Lcd display – Badger Meter Fluid Management System User Manual

Page 7

Advertising
background image

Installation & Operation Manual

OPERATION

The Electronic Preset Meter RF3 (EPM RF3) is equipped with RF (radio frequency) communications to communicate with a

fluid management system keypad to get authorization and dispense information. This is referred to in the manual as the

RF Mode.
The meter can also be run as a standard EPM. This is referred to in the manual as the EPM Mode. This is intended for start-up

purposes or when the fluid management system is not in use.
Once a work order has been entered at the keypad, the operator simply pushes the RESET button on the meter to start

communications between the meter and the keypad. The meter receives authorization from the keypad to unlock and the

dispense batch quantity. When the trigger is pulled the preset dispense batch quantity dispenses.
The meter automatically shuts off when the dispense batch quantity has been reached.
A Topoff feature allows additional fluid to be dispensed and tracked after the batch quantity has been dispensed.
Upon completion of the dispense, the operator presses the RESET button. The meter then locks, prohibiting any unauthorized

dispense of fluid to occur, and the dispense quantity is sent to the keypad.

Meter Buttons

10, 1, 0.1

Used to enter the dispense Batch quantity when

in the EPM Mode. These buttons are NOT used in

RF Mode.

TOTAL

Used to display the accumulated total of fluid

dispensed, as well as the re-settable total.

AUTO

Used to enter and exit the manual or batch mode

when in EPM mode. This button is NOT used in

RF mode.

RESET

Used to initiate RF communications from the

meter to the Keypad.

Used in EPM mode to clear the previous

batch.

Used to reset the re-settable total dispensed

while pressing the TOTAL button.

SHUTOFF

or

STOP

Used to stop the flow through an Emergency

Override.

LCD Display

1

2

3

4

5

6

7

1 Displays resettable total, accumulated total and scale

factor

2 Displays unit of measure

3 Arrows flash when RF communication is in progress with

the keypad

4 Preset Batch quantity

5 History Icon

6 AUTO is an indicator of being in EPM mode

7 Low Battery Icon