Changing the scale factor, Verifying changes, Enabling or disabling the epm (manual) mode – Badger Meter Fluid Management System User Manual

Page 18

Advertising
background image

Electronic Preset Meter Model EPM-3, RF 2.4 GHz

Changing the Scale Factor

IMPORTANT
Changing the Scale Factor changes the accuracy of the meter, potentially causing over-dispensing or under-dispensing of the liquid.

This has the potential to cause a mechanical breakdown.

Scale Factor Digits

1. Press the RESET button to advance through the Scale Factor digits.
2. Press the TOTAL button to change the selected number.

NOTE:

N

All digits can be scrolled between 0 and 9 except the first. It can only be scrolled

from 0 to 1 or from 1 to 0.

3. Press the RESET button advance to the next number in Scale Factor.
4. Repeat steps 2 and 3 for all five digits in Scale Factor.
5. If no Scale Factor changes are necessary, press and hold the TOTAL and AUTO buttons

until the display flashes three times, then goes blank

OR

Press the RESET button to advance to the EPM Manual Mode Enable screen.

Verifying Changes

Press and hold down the TOTAL and AUTO buttons at the same time to verify that the Scale Factor is correct.

Enabling or Disabling the EPM (Manual) Mode

To enable or disable the EPM mode:
1. Press the RESET button to advance to the AUTO icon on the display. There will be no

other icons flashing on the display.

.

2. Press the AUTO button to toggle the AUTO icon on and off.
When the icon is turned on the meter can be put in EPM mode through the special key

sequence on the meter keypad. When the AUTO icon is turned off the key sequence is

disabled and the meter cannot be put in EPM mode.
3. Press the RESET button to advance to the Network Program screen.

Unit of Measure

Scale Factor Digits

Page 18

November 2012

Advertising