Electronic Preset Meter Model EPM-3, RF 2.4 GHz

OPERATING MODE FUNCTIONS

These functions operate the same in RF Mode and EPM Mode.

Resettable/Accumulated Totals

The meter has two flow totalizers. One is Resettable Total the other is Accumulated Total.

1. Press and hold the TOTAL button to see the Accumulated Total.
2. Continue holding the TOTAL button for three seconds to see the Resettable Total.
RESETTOTAL displays the total fluid dispensed since the Resettable Total was last set back

to zero.
3. Press the RESET button while viewing RESETTOTAL to set it back to zero.
4. Release the TOTAL button to return to the operating display.

NOTE:

N

The Accumulated Total cannot be reset unless the you change the unit setting from English units to metric units or

from metric to English units. (Refer to the Change Factory Settings, Change Unit of Measure section of this manual).

Emergency Override

In case of an emergency or to interrupt a batch, the meter is equipped with an Emergency Override.

1. Press the red O button to activate the Emergency Override.

The override closes the valve, immediately stopping fluid flow.

2. Batching can continue after an Emergency Override by pulling up on the trigger.

Resettable Total