Communication cable overview – American Power Conversion SYMF800KH User Manual

Page 27

Advertising
background image

Symmetra MW 800 kW 3 × 400/230 V Installation - 990-1510D

21

Communication cable overview

C

o

n

n

e

c

ti

on pl

ane

0P

09

5

7

X131

X130

External

EPO

placed on

wall

X133A

2

1

X185

UPS

E

M

O

(

D

is

pl

ay

)

X134A

X128

1

1

2

2

X129

1

2

B

a

c

k

feed p

ro

te

c

ti

on

EPO out

EPO out

C

o

n

n

e

c

ti

o

n

p

la

n

e

0

P

0

9

5

7

External Bypass Static Switch

X128

X

126A

X

127A

X129

X131

X130

1

2

1

2

EM

O

(

D

is

pl

a

y

)

X134A

MBP CAN I/O board1

Maintenance Bypass Panel

Maintenance Bypass Panel

0P4533

C2

4

3

C1

2

1

X1

7

8

6

12

34

5

X1

7

3

M

B

P

B

re

a

k

e

rs

X1

7

6

8

71

0

91

2

11

X134A

X134B

Terminator

0N-0765

5

6

Q2

3

4

1

2

Q1

X177

1

2

X177

1

2

X177

1

2

X134A

X128

1

2

X129

7

10

11

X

1

7

3

M

B

P

B

re

a

k

e

rs

X172

Lamps

H6

10

9

H5

8

7

H4

6

5

H3

4

3

3

4

1

2

Q5

X176

11

12

2

1

C2

4

3

C1

2

1

X

1

7

8

X175

1

2

Norm.op

Relay output

X174

1

2

Earth fault sensor

5

6

Q6

Q

6

X177

1

2

Q

5

9

12

Q

4

8

Q

3

6

5

4

3

2
1

Q

1

2

1

X175

1

2

Norm.op

Relay output

X174

1

2

Earth fault sensor

X172

Lamps

X

128

1

2

X

129

1

2

MBP CAN I/O board 2

0P4533

4

3

2

1

12

11

8

7

10

9

6

5

X134B

Terminator

0N-0765

Q

2

+

-

External Lamp

supply V r V

o

Max. 250V 5A

+

- +

- +

- +

-

24V

Shunt trip for
back feed
protection

+

-

-

+

+

-

+

-

+

-

+

-

-

+

+

-

+

-

+

-

24V

Shunt trip

X

1

2

6

B

X

1

2

7

B

X

1

2

6

B

X

1

2

7

B

X

1

2

6

A

X

1

2

7

A

1

4

2 3

X170

1

4

2 3

X170

X186

Q7

1

2

3

4

Q8

X182

X133A

12

X185

Battery CAN I/O board

ID 0

0P4512

X1

8

0

1

4

2

3

X133B

Fu

se

1

1 2

Fu

se

2

3 4

Fu

se

3

5 6

Fu

se

4

7 8

1

2

3

X183

H7

H8

4

+

-

+

-

3

1

Temp sensor

+

+

4

2

-

X1

8

1

Temp sensor

NTC

NTC

-

3

1

Q8

Q7

UVR

+

+

4

2

UVR

-

-

X1

8

4

DC

DC

DC

DC

AC

Note 1

Note 1

Note 3

Note 2

Note 3

Note 1: Contact APC Application Team for correct
sizing.
Note 2: H7, H8 = 5V LED
Note 3: Q2, Q4 and Q6 are optional. If Q2 is not
present pins 3 and 4 must be shorted on both boards. If
Q4 is not present pins 7 and 8 must be shorted on both
boards. If Q6 is not present pins 11 and 12 must be
shorted on both boards.