Alarm data settings – Milestone XProtect Express 2014 User Manual

Page 171

Advertising
background image

Milestone XProtect

®

Express 2014

Administrator's Manual

www.milestonesys.com

171

Advanced configuration

Name

Description

Events triggered

Select the event to be triggered if the operator does not react
withing the time limit specified in Time limit. This could be, for
example, sending an email, SMS or similar.

Related cameras

Select (a maximum of 15) cameras for inclusion in the alarm
definition even though they are not themselves triggering the alarm.
This can be relevant, for example, if you have selected an external
event message (such as a door being opened) as the source of
your alarm. By defining one or more cameras near the door, you
could attach the cameras' recordings of the incident to the alarm.

Related map

Select a map to associate with the alarm definition.

The selected map is automatically be shown in XProtect Smart
Client whenever the alarm is listed. This might help you to quicker
identify the physical location of the alarm.

Initial alarm owner

Select a default user responsible for the alarm. You can only select
from users allowed to view all cameras and/or other devices
selected as source(s) for the event causing the alarm.

Initial alarm priority

Select a priority (High, Medium or Low) for the alarm. Priorities can
be used for sorting purposes and workflow control in the Smart
Client.

Initial alarm category

Select a category to which the alarm should initially be assigned.
This could be, for example, Building01, Burglary, ElevatorEast or
similar, depending on which categories have been defined.

Event triggered by alarm

Define an event to be triggered by the alarm in the Smart Client (if
needed).

Auto-close alarm

Select if the alarm should automatically be closed upon a particular
event. This is possible for alarms triggered by some (but not all)
events.

See also Alarm data settings (on page 171) and Alarm sound settings (see "Sound settings" on page
172) for further information on how to configure alarm settings.

Alarm data settings

When you configure alarm data settings, specify the following:

Alarm Data Levels tab, Priorities

Name

Description

Level

Add new priorities with level numbers of your choosing or use/edit
the default priority levels (numbers 1, 2 or 3). These priority levels
are used to configure the Initial alarm priority setting (see "Alarms
definition"
on page 170).

Name

Type a name for the entity. You can create as many as you like.