Manual recording – Milestone XProtect Express 2014 User Manual

Page 74

Advertising
background image

Milestone XProtect

®

Express 2014

Administrator's Manual

www.milestonesys.com

74

Advanced configuration

Name

Description

Post-recording

You can store recordings from periods following detected motion
and/or stop events. Select check box to enable this feature. Specify
the required number of seconds in the neighboring column.

Seconds [of post-recording]

Specify the number of seconds for which you want to record video
from after recording stop conditions (that is motion or stop event)
are met. Usually, only some seconds of post-recording is required,
but you can specify up to 65535 seconds of post-recording,
corresponding to 18 hours, 12 minutes and 15 seconds. However, if
specifying a very long post-recording time, you can potentially run
into a scenario where your post-recording time spans scheduled or
unscheduled archiving times. That can be problematic since post-
recording does not work well during archiving.

Camera

Click the Open button to configure detailed and/or camera-specific
settings (such as event notification, PTZ preset positions, and
fisheye view areas) for the selected camera.

Select All

Click button to select all cameras in the Apply Template column.

Clear All

Click button to clear all selections in the Apply Template column.

Set selected template value on
selected cameras

Apply only a selected value from the template to selected cameras.

Set all template values on
selected cameras

Apply all values from the template to selected cameras.

Manual recording

When you configure video and recording (see "About video and recording configuration" on page 63),
you can specify certain properties for many cameras in one go. In the case of manual recording, it is
because the properties are shared by all cameras.

When manual recording is enabled, XProtect Smart Client users with the necessary rights can
manually start recording if they see something of interest while viewing live video from a camera which
is not already recording.

If enabled, manual recording can take place even if recording for individual cameras (see "Recording"
on page 89) is set to Never or Conditionally.

When started from XProtect Smart Client, such user-driven recording always takes place for a fixed
time, for example for five minutes.

Name

Description

Enable manual recording

Select check box to enable manual recording and specify further
details.

Default duration of manual
recording

Period of time (in seconds) during which user-driven recording take
place. Default duration is 300 seconds, corresponding to five
minutes.