3 placing out of operation, 4 operation – NORD Drivesystems Berges-VG User Manual

Page 19

Advertising
background image

5.3

Placing out of operation

ƒ Place the drive out of operation by switching off the drive assembly.

Caution !

Lock the drive to prevent the power supply being switched on. ( Attach a corres-
ponding information sign to the switch-on point ).

ƒ If you intend to place the drive out of operation for a long period , operate the drive

briefly every 2 weeks. If you intend to place the drive out of operation for longer than
three months, remove the wide V-belt. ( see also Point 4.2, Page 14 ).

5.4

Operation

ƒ Check the VG for the following during operation:

- excessive operating temperature

- changed running and gearbox noises

Caution !

If irregularities such as those described above are detected during operation, shut
down the drive assembly immediately. The cause of the fault can then be determi-
ned using the fault-finding table ( see Chapter 7 - Troubleshooting ).

Possible faults and malfunctions, their causes and suggestions for remedying the
faults are contained in the "Fault-finding table".
If you are unable to establish the cause of the fault or if the fault cannot be remedied
using your resources, please contact one of our agents or one of our plants directly.
( see corresponding addresses Page 27 )