Troubleshooting

ƒ If faults or malfunctions occur when operating the BERGES attachments VG,

please check the possible causes of the fault on the basis of the table below.

ƒ If the fault cannot be remedied by any of the measures listed in the table or if the

fault which has occurred is not attributable to one of the causes specified in the
table please inform one of the BERGES service addresses.( See Service adresses,
Chapter 8, Page 27 )

Caution!
If faults necessitating repair of the VG occurs during the warranty period, such
faults may be remedied only by BERGES After-Sales Service. We advise you to
enlist the services of our After-Sales Servicing Department even if faults whose
cause cannot be clearly determined occur after the warranty period has expired.

Faults

Possible cause

Remedy

The drive does not start

Main motor not connected or

Check motor connection

connected incorrectly

Clearly audible running noise of

Wide V-belt contacting base

Set speed limitation correctly

the variable-speed drive

of hub

Changing running noises of the

Bearing defective

Replace dfective bearings ( Consult

reduction gear

After-Sales Sevicing Department )

Excessive bearing play

Set bearing play ( Consult After-
Sales Department )

Execssive external loading of

Correct loading to nominal data

drive or output

Rotational speeds specified on

Speed limitation not correctly

Set speed limitation correctly

the rating plate are not being

set

stellen

reached

Incorrect wide V-belt fitted

Fit correct wide V-belt ( See related
accompanying documents )

Indication of scale insert incorrect

Scale insert incorrectly fitted

Fit scale insert at max. set output
speed

Motor of the electrical remote

Motor not connected or

Check motor connection

control does not turning

connected incorrectly

Adjustment spindle blocked

Clear blockage with centring thread

of the motor of the electrical remote
control or turn the fan impeller

VG overheating

Fan cowl of the drive motor and/

Clean fan cowl, motor, fan cover

or VG heavily fouled

and surface of VG

Drop in speed or torque

Belt tension of the VG too

Fit a new wide V-belt

low - wide V-belt worn

Guide of variable-speed and/or

Replace variable-speed and/or

spring pulley worn

spring pulley

Drive starts sluggishly or not

Output subject to hight loading

Correct loading to nominal loading

at all