Fitting U and Z version ( see also Figures 3 and 4, Page 12 )

ƒ 1. First fit the new wide V-belt into the spring-loaded spring pulley F ( Item 2 ) and

thread it up by hand and then fit it into the fully-open mechanically adjustable
variable-Speed pulley R ( Item 1 ). Turn the drive by hand until the belt is taut.

ƒ 2. Bolt the halves of the housing ( Items 3 und 4 ) back together ( 4, 6 or 8

bolted connections )

ƒ 3. Conduct a trial run. When doing this, check the speed limits and the setting

of the speed indicators using a hand-held rev-counter. It may be necessary to
readjust the setting owing to allowable wide V- belt length tolerances ( see
see Chapter 6.2.2, Page 21 - 23 ).

Tip! U version, Figure 9

On sizes RGAE 4 to 9, the spring pulley F ( Item 2 ) can be opened by screwing a
bolt into the main hub flange against spring pressure. The wide V-belt can then be
fitted first into the open spring pulley F ( Item 2 ) and then into the open variable -
speed pulley R ( Item 1 ). Follow the reverse procedure when removing.

Caution!
Always remove the bolt again after fitting and prior to placing into operation.

Figure 9 Spring pulley F

Item 1 Only on sizes 4 - 9

Required bolt dimensions :
DIN 933

Size 4/210

M5 x 45

Size 5/250

M5 x 55

Size 5/280

M6 x 70

Size 6/300

M8 x 70

Size 6/350

M8 x 70

Size 7/375

M8 x 80

Size 7/400

M8 x 80

Size 8/450

M12 x 90

Size 8/500

M16 x 90

Size 9/600

M20 x 100

6.2.2

Setting the output speed

ƒ The output speed limits n

2max

and n

2min

are preset at the works ( only on com-

plete gears and RGAE with base / flange and mounted motor ). If there is heavy
wear orafter changing the wide V-belt, it may be necessary to readjust the speed
limits in line with the information on the rating plate ( Item 8.1, Figures 3 and 4 ).