Networking instructions for the ACS
Mitsubishi batch blender


Installing the PLC hardware
The first step is that you must install the Ethernet module and cable into
every PLC. You will need the Mitsubishi FX2N-232-BD board added to
each blender, an Digi One IA Ethernet Module (Digi p/n:70001862), and a
3 foot DB9 Null Modem Cable that is female on both ends (BlackBox.com
p/n EYN257H-0006-FF) per blender. The Ethernet module snaps in to the
DIN rail just to the right of the Mixer Motor contact and the cable snaps into
the module and 232 board on the PLC (follow the 232 boards instructions
for mounting:


You will also need to make sure that you are running at least SGB 1.2
blender software (this can be found on the blender under “Setup/F940
config”).





Follow the instructions on page 30 to setup and configure the Digi One IA
Ethernet Module.