background image

Maintenance and Cleaning

63

Maintenance and Cleaning

When the projection lamp of the projector

reaches its end of life, the Lamp replacement

icon appears on the screen and LAMP

REPLACE indicator lights yellow. Replace the

lamp with a new one promptly. The timing when

the LAMP REPLACE indicator should light is

depending on the lamp mode.

Follow these steps to replace the lamp.

For continued safety, replace with a lamp of the

same type. Do not drop a lamp or touch a glass

bulb! The glass can shatter and may cause

injury.

Allow a projector to cool for at least one hour

before you open the Lamp Cover. The inside

of the projector can become very hot.

CAUTION

Unplug the AC power cord. Let the projector

cool for at least one hour.

Loosen the three (3) screws that secure the

lamp. Lift the lamp out of the projector by

using the handles.

1

3

Replace the lamp with a new one and

secure the three (3) screws. Make sure that

the lamp is set properly. Close the lamp

cover and secure the screw.

4

Loosen the screw and open the lamp cover.

2

Connect the AC power cord to the projector

and turn on the projector.

5

Lamp Replacement

CAUTION

Top Control

CAUTION

When replacing the lamp because it has stopped illuminating, there is a possibility that the lamp

may be broken.

If replacing the lamp of a projector which has been installed on the ceiling, you should always

assume that the lamp is broken, and you should stand to the side of the lamp cover, not

underneath it. Remove the lamp cover gently. Small pieces of glass may fall out when the lamp

cover is opened. If pieces of glass get into your eyes or mouth, seek medical advice immediately.

Note:

• The image will be displayed for about 10 seconds.
• The Lamp replacement icon will not appear when the Display function is set to

Off (p.48), during Freeze (p.27),

or

Blank (p.28).

Lamp replacement icon

OK

POWER

AUTO SET

MENU

LAMP REPLACE

WARNING

Reset the lamp counter.

See "Lamp Counter" on page 57.

6

Screw

Handles

Screw

Screw

Lamp

LAMP

REPLACE

indicator

lights yellow

Lamp Cover

Screw