Overview of condensing tankless gas water heater – Electrolux EP19WI30LS User Manual

Page 10

Advertising
background image

8

Cold wate

r

Cold wate

r

Gas

Gas

Hot water

Hot water

Condensate

Combustion gas

About

400˚F (200˚C)

Exhaust

Exhaust

About

120˚F (49˚C)

Conventional

type

Condensing

Tankless Gas

Water Heater

Water is heated
using the exhaust
gas which is about
400˚F (200˚C).

Primary heat exchanger

Primary heat exchanger

Secondary heat exchanger

condensate trap

Combustion gas

About

400˚F (200˚C)

About

400˚F (200˚C)

The condensing tankless gas water
heater discharges condensate.

When heat from the exhaust gas is collected within
the secondary heat exchanger, condensation occurs
from moisture in the exhaust gas and the resulting
water is discharged from the drain pipe (approx.
2 gallons/hour (7.5 liters/hour) maximum). It is not a
water leak. Do not plug or block the drain line as it
must always be allowed to freely flow.

Note : The condensate discharged is acidic with a

pH level of approximately 2-3.

A condensate neutralizer may be required by
local code prior to disposal.

Drain pipe

(Installation example)

Overview of Condensing Tankless Gas Water Heater

This water heater is a high efficiency, fully condensing appliance. Unlike a traditional tankless water
heater, a condensing type captures heat from the exhaust gas and uses it to preheat the incoming
cold water as it passes through the secondary heat exchanger as illustrated below.

The condensing tankless gas
water heater tends to show
white steam.

After the exhaust gas passes through the
secondary heat exchanger, it becomes low in
temperature and moisture rich which tends to
produce steam at the vent discharge terminal.
This is a normal occurrence.

Condensate
comes out
from here.

During combustion, white
steam may often be seen.
This is normal.

(Ex. EN18WI30LS)