Specifications-1, Specifications performance – Electrolux EP19WI30LS User Manual

Page 33

Advertising
background image

31

Specifications-1

r4QFDJàDBUJPOTNBZCFDIBOHFEXJUIPVUQSJPSOPUJDF
r5IFDBQBDJUZNBZEJGGFSTMJHIUMZ EFQFOEJOHPOUIFXBUFSQSFTTVSF 

water supply, piping conditions, and water temperature.

Specification

EN18WI30LS EP18WI30LS

Indoor Wall Mounted

Direct Ignition

15-150 psi

(1. -NJO

 NN Y NN Y NN

58 lbs.

0.5 Gallon (1.8L)


u
u

u5ISFBEFE

120 VAC (60Hz)

73W

4UBJOMFTT4UFFM;JODJàFE4UFFM1MBUF

PVC

Copper Sheeting, Copper Tubing

Stainless Steel Sheeting, Stainless Steel Tubing

Flame Rod, Thermal Fuse, Lightning Protection

Device (ZNR), Overheat Prevention Device, Freezing

Prevention Device, Fan Rotation Detector

Remote Controller, Remote Controller Cord,

Anchoring Screws

Specifications

Performance

Item

Model Name

Type

Ignition

Operating Pressure

Minimum Flow Rate

Dimensions (Height) x (Width) x (Depth)

Weight

Water Holding Capacity

Accessories

Installation
"JS4VQQMZ&YIBVTU

Connection Sizes

Power Supply

Materials

Water Inlet

Hot Water Outlet

Gas Inlet

Condensate Drain

Safety Devices

Item

Gas
Consumption

Maximum Hot Water Capacity

Capacity Range

Temperature Settings

Default Temperature Options

NG

LP

45°F (25°C) Rise

Maximum Performance

180,000 btuh

180,000 btuh

Minimum Performance

16,000 btuh

16,000 btuh

(1. -NJO

(1. -NJO

100-140°F (In 5°F intervals) (9 Options)

Casing

Flue Collar

Primary Heat Exchanger

Secondary Heat Exchanger

Supply

Consumption

120°F (50°C), 130°F (55°C), 140°F (60°C)

(Original is 120°F (50°C))

°F Mode:

°C Mode:

37-48°C (In 1°C intervals),

50,55,60°C (In 5°C intervals) (15 Options)

Power Vented

78W

Freeze Prevention 213W

Advertising
This manual is related to the following products: