Periodic Maintenance

If the water drain valve (with water filter) is covered with debris, the hot water may not run
smoothly, or the unit may put out cold water. Check and clean the filter as explained below.
* To avoid burns, wait until the equipment cools down before draining the water.

The appliance will remain hot after it is turned off.

Water Drain Valve (with Water Filter)

1. Close the water supply valve.
2. Open all hot water fixtures.
3. With a bucket ready, remove the inlet and outlet

drain plugs (For EN18WI30LS and EP18WI30LS,
about 0.4 gallon (1.4L) will drain out.

For EN19WI30LS and EP19WI30LS,
about 0.45 gallon (1.7L) will drain out.)

4. Take the water drain valve (with water filter) out of

the inlet. (See illustration to right).

5. Clean the water drain valve (with water filter) with

a brush under running water.

6. Replace the water drain valve (with water filter)

and close the drain plugs.

(Take care not to lose the packing.)
7. Close all hot water fixtures.
8. Open the water supply valve and check that
water does not leak from the drain plugs or water

drain valve (with water filter).

Optional Maintenance

* Isolation valves may be purchased as an

accessory from Electrolux.

They allow for full diagnostic testing and easy

flushing of the system.

* The kit includes two full port isolation valves

and a pressure relief valve for the hot side.

Contact Electrolux for more information.

Isolation Valves

Water Supply
Valve

Inlet

Packing

Water drain valve
(with water filter)

Water Intlet

Water Outlet

Drain

Hot Water
Service Valve

Pressure Relief Valve

Cold Water
Service Valve

(Ex. EN18WI30LS)

(Ex. EN18WI30LS)