Master programming mode – Water Inc SXT Timer User Manual

Page 14

Advertising
background image

Page 14

11. Day Override (Display Code DO)

Press the Extra Cycle button. Use this display to set the Day Override. This setting specifies the maximum

number of days between regeneration cycles. If the system is set to a timer-type control, the day override setting

determines how often the system will regenerate. A metered system will regenerate regardless of usage if the

days since last regeneration cycle equal the day override setting. Setting the day override value to “OFF” disables

this function. This option setting is identified by “DO” in the upper left hand corner of the screen. Use the Up and

Down buttons to adjust the value as needed.

12. Regeneration Time

Press the Extra Cycle button. Use this display to set the Regeneration Time. This setting specifies the time of day

the control will initiate a delayed, manually queued, or day override triggered regeneration. This option setting is

identified by “RT” in the upper left hand corner of the screen. Use the Up and Down buttons to adjust the value as

needed..
.
.

.

13. Regeneration Cycle Step Times

Press the Extra Cycle button. Use this display to set the Regeneration Cycle Step Times. The different

regeneration cycles are listed in sequence based on the valve type selected for the system, and are identified

by an abbreviation in the upper left-hand corner of the screen. The abbreviations used are listed below. If the

system has been configured with the “OTHER” valve type, the regeneration cycles will be identified as R1, R2,

R3, R4, R5, and R6. Each cycle step time can be set from 0 to 199 minutes, or “OFF.” Setting a cycle step to

“OFF” will disable all of the following steps. Setting a cycle step time to 0 will cause the control to skip that step

during regeneration, but keeps the following steps available. Use the Up and Down buttons to adjust the value as

needed. Press the Extra Cycle button to accept the current setting and move to the next parameter.

Cycle Step

Abbreviation

BD

Brine Draw

BF

Brine Fill

BW

Backwash

RR

Rapid Rinse

SV

Service






Master Programming Mode

CAUTION: Before entering Master Programming, please contact your local professional water dealer.

Advertising