Timer features, Page 4, Features of the sxt – Water Inc SXT Timer User Manual

Page 4: Setting the time of day

Advertising
background image

Page 4

Timer Features

Features of the SXT:

Power backup that continues to keep time and the passage of days for a minimum of 48 hours in the event of

power failure. During a power outage, the control goes into a power-saving mode. It does not monitor water

usage during a power failure, but it does store the volume remaining at the time of power failure.

Settings for both valve (basic system) and control type (method used to trigger a regeneration).

Day-of-the-Week controls.

While in service, the display alternates between time of day, volume remaining or days to regeneration, and

tank in service (twin tank systems only).

The Flow Indicator flashes when outlet flow is detected.

The Service Icon flashes if a regeneration cycle has been queued.

A Regeneration can be triggered immediately by pressing the Extra Cycle button for five seconds.

The Parameter Display displays the current Cycle Step (BW, BF, RR, etc) during regeneration, and the data

display counts down the time remaining for that cycle step. While the valve is transferring to a new cycle step,

the display will flash. The parameter display will identify the destination cycle step (BW, BF, RR, etc) and the

data display will read “----”. Once the valve reaches the cycle step, the display will stop flashing and the data

display will change to the time remaining. During regeneration, the user can force the control to advance to

the next cycle step immediately by pressing the extra cycle button.

Setting the Time of Day

Press and hold either the Up or Down buttons until the programming icon replaces the service icon and the

parameter display reads TD.

Adjust the displayed time with the Up and Down buttons.

When the desired time is set, press the Extra Cycle button to resume normal operation. The unit will also

return to normal operation after 5 seconds if no buttons are pressed.






1.

2.
3.

Parameter

Display

Data

Display

PM

Indicator

Flow Indicator

x1000 Indicator

Service

Icon

Programming

Icon

Extra Cycle

Button

Up

Button

Down

Button

Error/

Information

Icon