Troubleshooting – Water Inc SXT Timer User Manual

Page 34

Advertising
background image

Page 34

Troubleshooting

Error Codes

Note:

Error codes appear on the In Service display.

Error Code

Probable Cause

Recover and Resetting

[Err.0]

Drive motor is stalled

Unplug the unit from the power source

[Err.1].

Drive motor is running continuously

When power is restored to the unit, the Err _

display code clears. If the condition causing

the error has not been resolved the Err _ code

reappears in the four digit display. Do not at-

tempt to troubleshoot this problem any further.

[Err.2]

There have been more than 99

days since the last Regeneration.

If the Day of the Week mode of

regeneration is selected and days

since last regeneration exceeds 7

days.

[ 7 - - 5 ]

: There have been more

than 7 days since the last regen-

eration. All individual settings (d1,

d2, d3, d4, d5, d6, d7) are set to 0.

Regeneration must occur for the unit to

recover, the display to clear and the valve to

function normally.

[ 7 - - 5 ]

: To recover from [Err2], the user

must initiate a regeneration or set at least one

individual day to 1.

[Err.3]

Control board memory failure.

Perform a Master Reset. If the error returns,

do not attempt to troubleshoot this problem

any further.

Error Display Example




NOTE: Unit will flash when an error exists.