User programming mode – Water Inc SXT Timer User Manual

Page 17

Advertising
background image

Page 17

User Programming Mode

User Programming Mode Options

Abbreviation

Parameter

Description

DO

Day Override

The timer’s day override setting

RT

Regeneration Time

The time of day that the system

will regenerate (meter delayed,

timeclock, and day-of-week

systems)

H

Feed Water Hardness

The hardness of the inlet water

- used to calculate system capacity

for metered systems

RC

Reserve Capacity

The fixed reserve capacity

CD

Current Day

The current day of week

NOTES:

Some items may not be shown depending on timer configuration.
The timer will discard any changes and exit User Mode if any button is not pressed for sixty seconds.

User Programming Mode Steps

Press the Up and Down buttons for five seconds while in service, and the time of day is NOT set to 12:01 PM.

Use this display to adjust the Day Override. This option setting is identified by “DO” in the upper left hand

corner of the screen..
.
.
.
.
.
.

Press the Extra Cycle button. Use this display to adjust the Regeneration Time. This option setting is identified

by “RT” in the upper left hand corner of the screen..
.
.
.
.
.
.

Press the Extra Cycle button. Use this display to adjust the Feed Water Hardness. This option setting is

identified by “FH” in the upper left hand corner of the screen..
.
.
.
.
.
.

Press the Extra Cycle button. Use this display to adjust the Fixed Reserve Capacity. This option setting is

1.
2.

3.

4.

5.