Master Programming Mode Chart

Master Programming Options

Abbreviation

Parameter

Option

Abbreviation

Options

DF

Display Format

GAL

Gallons

Ltr

Liters

Cu

Cubic Meters

VT

Valve Type

St1b

Standard Downflow/Upflow Single Backwash

St2b

Standard Downflow/Upflow Double Backwash

Fltr

Filter

UFbF

Upflow Brine First

Othr

Other

CT

Control Type

Fd

Meter (Flow) Delayed

FI

Meter (Flow) Immediate

tc

Time Clock

dAY

Day of Week

NT

Number of Tanks

1

Single Tank System

2

Two Tank System

TS

Tank in Service

U1

Tank 1 in Service

U2

Tank 2 in Service

C

Unit Capacity

Unit Capacity (Grains)

H

Feedwater

Hardness

Hardness of Inlet Water

RS

Reserve Selection

SF

Percentage Safety Factor

rc

Fixed Reserve Capacity

SF

Safety Factor

Percentage of the system capacity to be used as a

reserve

RC

Fixed Reserve

Capacity

Fixed volume to be used as a reserve

DO

Day Override

The system’s day override setting

RT

Regen Time

The time of day the system will regenerate

BW, BD, RR,
BF

Regen Cycle Step

Times

The time duration for each regeneration step. Adjust-

able from OFF and 0-199 minutes..
NOTE: If “Othr” is chosen under “Valve Type”, then
R1, R2, R3, etc, will be displayed instead

D1,.D2,.D3,.D4,.

D5, D6, & D7

Day of Week

Settings

Regeneration setting (On or OFF) for each day of the

week on day-of-week systems

CD

Current Day

The Current day of the week

CAUTION: Before entering Master Programming, please contact your local professional water dealer.