Device Manager Menus

UPS Status

FRQWLQXHG

Fault Tolerance
(Symmetra or
Symmetra 3 Phase
UPS)

Two fault-tolerance fields are available for Symmetra and Symmetra 3
Phase UPS models.

Note:

In the Control Console, you use the

Detailed UPS Information

option to access the fault tolerance status.

Battery

The following table uses footnotes to indicate which output-power fields
are shared by which

UPS

models (only the status field,

Runtime

Remaining

, is shared by all UPS models).

6WDWXV )LHOG

'HILQLWLRQ

Present KVA
Capacity

Identifies the maximum load that the Symmetra can support.

Redundancy

Identifies the number of power modules which can fail or be
removed without causing the Symmetra to switch to bypass.

6WDWXV )LHOG

'HILQLWLRQ

Battery Capacity

1

Identifies how much of the

UPS

battery capacity is available to

support the attached equipment.

Battery Current

2

Identifies the current which is being output from the battery.

Battery Voltage

3

,

Actual Battery
Voltage

2

, or Actual

Battery Bus
Voltage

4

Identifies the available DC power.

Calibration Date

1

Identifies when the last runtime calibration was performed.

Calibration Result

1

Identifies the result of the last runtime calibration.

Nominal Battery
Voltage

5

Identifies the basic voltage range that the battery needs to
supply when the

UPS

uses its battery for output power.

Note:

This field only appears in the Web Interface.

Number of Bad
Batteries

1

Identifies how many of the UPS batteries need replacing.

Note:

This field only appears when the

UPS

has at least one

external battery.

Number of
Batteries

3

or

Number of External
Batteries

6

Identifies how many batteries the

UPS

has.

Runtime
Remaining

Identifies how long the

UPS

can use battery power to support its

attached equipment.

Self-Test Result

1

Identifies the result of the last self-test.

Self-Test Date

1

Identifies when the last self-test was performed.

1

Smart-UPS, Matrix-UPS, Symmetra, or Symmetra 3 Phase UPS

2

Symmetra 3 Phase or Silcon DP300E series UPS

3

Smart-UPS or Matrix-UPS

4

Symmetra 3 Phase UPS

5

Symmetra, Symmetra 3 Phase, or Silcon DP300E series UPS

6

Symmetra or Symmetra 3 Phase UPS