Configuring the lo100 serial port – HP ProLiant DL145 G3 Server User Manual

Page 12

Advertising
background image

Configuration 12

d.

Press the down arrow (↓) key to scroll to Serial Port Connection Mode. Select Direct.

e.

Press the Esc key to return to the Advanced menu.

f.

Press the down arrow (↓) key to scroll to IO Device Configuration. Press the Enter key.

g.

Select Serial Port 1 and press the Enter key to toggle between Enabled and Disabled. Select
Enabled.

o

On HP ProLiant DL140 G3 servers:

a.

Press the down arrow (↓) key to scroll to IO Device Configuration. Press the Enter key.

b.

Press the down arrow key (↓) to scroll to the Serial Port menu. Press the Enter key to toggle
between Serial, Shared, and BMC. Select Shared.

c.

Press the down arrow (↓) key to scroll to Serial Port A. Select Enabled.

d.

Press the Esc key to return to the Advanced menu.

e.

Press the down arrow (↓) key to scroll to IPMI. Press the Enter key.

f.

Press the down arrow (↓) key to scroll to the LAN Settings submenu. Press the Enter key.

g.

Confirm the following settings:

BMC Telnet Service: [Enabled]

BMC Ping Response: [Enabled]

BMC HTTP Server: [Enabled]

o

On HP ProLiant DL145 G3 servers:

a.

Press the down arrow (↓) key to scroll to IO Device Configuration. Press the Enter key.

b.

Press the down arrow key (↓) to scroll to the Serial Port Mode. Press the Enter key to toggle
between Serial, Shared, and BMC. Select Shared.

c.

Press the down arrow (↓) key to scroll to Serial Port A. Select Enabled.

d.

Press the Esc key to return to the Advanced menu.

5.

Press the F10 key to save and exit.

Configuring the LO100 serial port

1.

Power on the server by pressing the Power On/Off button on the front panel.

2.

When POST displays the message, ROM-Based Setup, press the F10 key. If the server has an

administrator password configured, the system prompts you to enter the password. If the server does

not have a password configured, the main screen of the BIOS Setup Utility appears.

3.

Press the right arrow (→) key to navigate to the Advanced menu.

4.

Choose one of these options:

o

On ML110 G4 servers, perform the following steps:

a.

Press the down arrow (↓) key to scroll to the Console Redirection menu. Press the Enter key.

b.

Set Serial Port Address to COM A.

o

On ML115 G1 servers, perform the following steps:

a.

Press the down arrow (↓) key to scroll to the Console Redirection menu. Press the Enter key.

b.

Set Console Redirection to Enabled.

c.

Press the Esc key to return to the Advanced menu.

d.

Press the up arrow (↑) key to scroll to the IO Device Configuration menu. Press the Enter key.