Microsoft windows ems management – HP ProLiant DL145 G3 Server User Manual

Page 45

Advertising
background image

Using LO100 45

Baud Rate—115.2K

Console Type—VT100

Continue C.R. after POST—On

I/O Device Configuration

Serial Port A—Enabled

Base I/O address—3F8

Interrupt—IRQ 4

2.

In the /boot/grub/menu.lst file, append the following to the kernel startup line:
console=ttyS0 115200
Comment out the line GRAPHICAL DISPLAY LINE
# splashimage=(hd0,0)/grub/splash.xpm.gz

3.

Add an entry to allow serial console login in /etc/inittab. For example:
S0:12345:respawn:/sbin/agetty -L 115200 ttyS0 vt102

4.

In /etc/securetty enable root access to ttyS0 by adding ttyS0.

5.

In /etc/sysconfig/kudzu, set kudzu to not perform serial port probing during boot. For example:
SAFE=yes

6.

After modifying and saving the previous files, reboot the server. You can now log in to the operating
system through remote console.

After POST, in the remote console, the server prompts you with a login. Enter a valid login and use the

server as you normally would. Use the ESC+Q keys to start remote console through the telnet and the
ESC+( keys to exit the remote console in telnet.

Microsoft Windows EMS management

Microsoft® Windows Server™ 2003 provides text-based console access. You can connect a notebook to
LO100 to perform basic management tasks on the target system. The Windows® EMS Console, if

enabled, displays the processes that are running and enables administrators to halt processes. This

capability is important in cases in which video, device drivers, or other operating system features have

prevented normal operation and normal corrective actions.
To enable Windows® EMS management on the target system:

1.

Press the F10 key during POST to enter the BIOS Setup Utility.

2.

Press the right arrow (→) key to navigate to the Advanced>Console Redirection menu.

3.

Choose one of these options:

o

On ProLiant ML110 G4, ProLiant DL140 G3, ProLiant DL145 G3, and ProLiant ML150 G3

servers, press the down arrow (↓) key to scroll down to the EMS Console option, and press the
Enter key to access the submenu. Verify the following settings:

Console Redirection—Enabled

Baud Rate—115.2K

Terminal Type—VT100+

Flow Control—None

Redirection after BIOS POST—On