Register send-alarm-to-server event, Interface uri, Access method – HP Intelligent Management Center Licenses User Manual

Page 311: Returned result, Interface uri access method returned result

Advertising
background image

Register Send-Alarm-to-Server Event

Register the send-alarm-to-server event and filter alarms to be sent with certain criteria.

Interface URI

/events

Access Method

HTTP

GET

Parameters

Query parameters

Event type.

type

Integer type. The value is 11, indicating the send-alarm-to-server event.

UUID.

uuid

String type. Uniquely identifies a client.

Alarm level.

alarmLevel

Integer type, supporting multiple elements. Optional. No default value. If this parameter is not set,
then all levels of alarms will be forwarded. For the valid values, see Query Alarm Levels.

Custom view ID.

customView

Long integer type. Optional. No default value.

Device IP address.

deviceIp

String type, supporting multiple elements. Optional. No default value.

IP segment.

ipSegment

String type, supporting multiple elements. Optional. No default value. The IP range is expressed with
a hyphen (-). For example, 192.168.0.1-192.168.0.254.

Alarm event OID.

eventOid

String type, supporting multiple elements. Optional. No default value.

Returned Result

Status codes

202 (Accepted): Successfully registered.

Message header

HTTP/1.1 202 Accepted
Content-Type: application/xml

Register Send-Alarm-to-Server Event