HP ProLiant SL2x170z G6 Server User Manual

Page 40

Advertising
background image

Press the down arrow (

↓) key to scroll down to the Console Redirection option, and

press the Enter key.

a.

b.

Set BIOS Server console to Enabled.

Baud Rate—9600 (this is the only setting that can be changed)

On ML150 G6 servers:

Press the down arrow (

↓) key to scroll down to the Console Redirection option, and

press the Enter key.

a.

b.

Verify the following settings:

Console Redirection—Enabled

Serial Port Mode—9600 8,n,1

Terminal Type—VT100+

Flow Control—None

Redirection after BIOS POST—On

On DL160 G6, DL160se G6, DL170h G6, DL170e G6, DL180 G6, SL165s G7, SL160z
G6, SL170z G6, SL170s G6, SL2x170z G6, DL165 G7, and SL165z G7 servers:
a.

Press the down arrow (

↓) key to scroll down to the Remote Access Configuration

option, and then press the Enter key.

b.

Verify the following settings:

Remote Access—Enabled

EMS support(SPCR)—Enabled

Base Address—IRQ4/3F8

Serial Port Mode—9600 8,n,1

Flow Control—None

Terminal Type—VT100

Redirection after BIOS POST—Enabled

4.

Press the Esc key to return to the previous screen.

5.

Scroll to the I/O Device Configuration option, and press the Enter key.

6.

Verify that Serial Port is set to Enabled.

7.

Follow the instructions in

“Network settings” (page 46)

to set or obtain a valid IP address.

8.

Press the F10 key to save and exit.

After completing the console redirection process, you can view the boot process remotely from a
client PC through an established Telnet session to the IP address of LO100. See your operating
system documentation for instructions on establishing Telnet sessions.

To redirect the console to the Telnet session and view the boot process, press the Esc+Q keys in
the Telnet session during server boot. If you reset the server using the Telnet connection, and press
the Esc+Q keys, the boot process might not appear immediately. The boot process appears after
the server resets. To exit the console redirection and return to CLP, end this session by pressing the
Esc+( keys.