Redirecting a Linux console

In the remote console and servers with the Linux operating system, you can enable a remote login
on ttyS0 by making the following changes to the BIOS Setup Utility and boot documents.

NOTE:

The actual steps will vary depending on your version of Linux.

1.

Using the BIOS Setup Utility, verify your system configuration by choosing one of these options
based on your server model:

On ML110 G6 and DL120 G6 servers, verify the following settings:

Console Redirection

BIOS Serial console—Enabled

Baud Rate-9600

I/O Device Configuration

Embedded Serial Port Mode—BMC

Embedded Serial Port—Enabled

On ML150 G6 servers, verify the following settings:

Console Redirection

BIOS Serial console—Enabled

EMC Support (SPCR)—Enabled

Serial Port Mode—9600 8,n,1

Console Type—VT100

Continue C.R. after POST—On

I/O Device Configuration

Serial Port A—Enabled

Base I/O address—3F8

Interrupt—IRQ 4

On DL160 G6, DL160se G6, DL170h G6, DL170e G6, DL180 G6, SL160s G6, SL160z
G6, SL165s G7, SL170z G6, and SL2x170z G6 servers, and SL165z G7 servers, verify
the following settings:

Remote Access Configuration

NOTE:

For the SL160s G6 server, the setting should be SuperIO Configuration.

Serial Port Address—3F8

Serial Port IRQ—IRQ 4

Remote Access—Enabled

EMS support(SPCR)—Enabled

Terminal Type—VT100

Accessing the remote console through Telnet