Using VLAN Tagging

VLAN tagging is used to isolate the (internal) management traffic from the production traffic (for
security and configuration simplicity) without running multiple Ethernet drops to each server. Though
VLAN tagging adds some network configuration complexity, significant networking cost savings
(as in ports and cables) can be realized.

Server Support

VLAN tagging is supported on all ProLiant 100 series G5/G6/G7 servers when used with the
dedicated management port.

NOTE:

VLAN tagging on the low-speed shared management ports on ML110 G6, DL120 G6,

or ML150 G6 requires firmware version 4.22 or later.

Configuring VLAN Tagging using IPMI commands

The following host-based configuration commands are used to configure VLAN tagging:

To set a VLAN ID using an IPMI command type the following:

linux: ipmitool raw 0x0c 0x01 0x02 0x14 XX YY

Where:

XX = least significant 8 bits of the VLAN ID

YY = bit 7 - 1=enable VLAN; 0=disable

bit [6:4] – 0=Reserved

bit [3:0] - most significant 4 bits of the VLAN ID

For example, to enable VLAN ID-809, type the following command:

linux: ipmitool raw 0x0c 0x01 0x02 0x14 0x29 0x83

Configuring VLAN Tagging using a web browser

For more information, see

“Configuring network settings using a web browser” (page 46)

.