Using tcp/ip over ethernet management port, Selecting a shared ethernet management port – HP ProLiant SL2x170z G6 Server User Manual

Page 10

Advertising
background image

8.

Review the serial port settings, and make sure the settings match the serial port communications
software settings used to connect to LO100.

9.

To return to the previous screen, press the Esc key, or to save the changes and exit Setup,
press the F10 key.

Using TCP/IP over Ethernet management port

You can configure LO100 LAN port access using two different Ethernet ports: the dedicated 10/100
LO100 management port or through a side-band connection using the server embedded NIC. The
side-band, shared, or UMP options utilize one server Ethernet port for both server network traffic
and LO100 network traffic reducing the number of network cables that you must attach to the
server.

NOTE:

Not all servers come with the option of selecting a sideband or dedicated NIC. Some

have only one option.

NOTE:

Note, when a dedicated setting is selected in the IPMI LAN configuration of the RBSU, a

dedicated Optional LO100i 10/100 Mbps LAN port for dedicated IPMI management (RJ-45) is
required to be installed in the server in order for the Lights-Out management to work.

Selecting a shared Ethernet management port

1.

Power on the server by pressing the Power On/Off button on the front panel.

2.

When POST displays the message, ROM-Based Setup, press the F10 key. If the server has
an administrator password configured, the system prompts you to enter the password. If the
server does not have a password configured, the main screen of the BIOS Setup Utility appears.

3.

Press the right arrow (

→) key to navigate to the Advanced menu.

NOTE:

On the ML150 G6, ML110 G6, and DL120 G6 systems, the Virtual KVM and Virtual

Media functions are not available when used with the Shared NIC function. If you want LO100
Advanced Pack features on the ML150 G6, use the dedicated NIC mode.

4.

Press the down arrow (

↓) key to scroll to IPMI Configuration. Press the Enter key.

5.

Scroll to the LAN Configuration menu by pressing the down arrow (

↓) key. Press the Enter

key.

6.

Choose one of these options:

On ML110 G6 or DL120 G6, press the down arrow (

↓) key to IPMI. Press the Enter key,

and then set BMC NIC Allocation to Shared.

On ML150 G6, set BMC NIC Mode to Shared.

On DL160 G6, DL160se G6, DL170h G6, DL180 G6, SL160s G6, and SL160z G6,
SL170z G6, SL2x170z G6, SL165s G7, DL165 G7, DL170e G6, set BMC NIC Allocation
to Enabled.

On DL165 G7, press the down arrow (

↓) key to BMC NIC Allocation, then select

Dedicated/Shared. Press the Enter key.

7.

To return to the previous screen, press the Esc key, or to save the changes and exit Setup,
press the F10 key.

The TCP/IP over Ethernet management port, whether dedicated or shared, is a standard Ethernet
10/100Mb interface that connects to the network using a standard Ethernet cable. Before using
the dedicated management port, you must determine the DHCP IP address or set a static IP address.

10

Configuration