Managing fabrics, Define san fabric screen – HP Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 106

Advertising
background image

Virtual Connect fabrics 106

To create a proper Virtual Connect fabric, all VC-FC uplinks that are included in the fabric must be connected
to the same physical SAN fabric. If the fabric uplinks are not connected to the same SAN fabric, then the

fabric becomes degraded and a log message indicates that the uplinks are connected to different SAN
switches. The WWN of the principal fabric switch indicates connectivity to the same SAN fabric in Virtual
Connect.
The VC-FC module uses dynamic login distribution to provide the following:

Load balancing as new server HBA logins are completed through the uplink port with the least amount

of active logins

A failover path if an uplink becomes unusable

Managing fabrics

Use the following screens to manage fabric settings:

Define SAN Fabric screen (on page

106

)

o

Define a SAN fabric, including selecting login re-distribution for SAN fabrics using HP VC
FlexFabric 10Gb/24-port Modules

SAN Fabrics (External Connections) screen (on page

112

)

o

View of list of SAN fabrics with external connection information

o

Add, edit, or delete a fabric

o

Redistribute logins on a SAN fabric

SAN Fabrics (Server Connections) screen (on page

113

)

o

View a list of SAN fabrics with server connection information

o

Delete a fabric

o

Redistribute logins on a SAN fabric

o

Define a SAN fabric

Edit SAN Fabric screen (on page

110

)

o

Modify a fabric name

o

Set the uplink port speed

o

Change the login re-distribution

o

Add or delete an uplink port

Fibre Channel Settings (Misc.) screen (on page

115

)

o

Set the time interval to wait after a link becomes unstable before automatic redistribution occurs
within the fabric

Define SAN Fabric screen

To define a SAN fabric, select the Define SAN Fabric link on the home page, click Define SAN Fabric on the

SAN Fabrics (Server Connections) ("

SAN Fabrics (Server Connections) screen

" on page

113

) screen, or

select SAN Fabric from the Define pull-down menu.
Only connect HP VC 4Gb FC module, HP VC 8Gb 24-Port FC module, HP VC 8Gb 20-Port FC module, or

FlexFabric FC uplinks to Fibre Channel switch ports that are NPIV-enabled.

Advertising