HP Systems Insight Manager User Manual

Page 132

Advertising
background image

Solution: If this occurs, Systems Insight Manager will not add the cluster and the cluster nodes will not be
associated in Systems Insight Manager with the cluster. To work around this, add an entry to the hosts file
on the Systems Insight Manager server for the cluster alias name and IP. On Windows, the host file is located
in the %windir%/system32/drivers/etc directory. The standard hosts file entry should be of the
following form: 15.2.9.1 hypcl1.vse.adapps.hp.com hypvcl1.

-------------------------------------------------------------
Discovery of an MSCS cluster service name or IP address (for example. a Fileserver service, and so on)
overwrites MSCS system information, making management of the cluster nodes through Systems Insight
Manager, HP Insight Control virtual machine management, or HP Insight Dynamics impossible.
Solution: Remove all systems associated with the MSCS cluster (this includes the cluster alias, the cluster
nodes, and any VMs that might be running on the cluster), and then re-discover the cluster (and any VMs)
without discovering the service. For example, add the IP address of the cluster service to the ping exclusion
range on the general discovery settings page.
-------------------------------------------------------------

When the number of objects to be collected on any given storage array exceeds the value of ~2500, it is
possible that data collection will fail for the array.

Solution: This is due to a default timeout value of three hours for this operation. There are two ways to resolve
the issue:

Configure the array to have a maximum of 2500 collectible objects (volumes, disks, ports, and so on).

Increase the timeout value, depending on the configuration, to an optimal value by modifying the
configurable parameter

Storage_DC_Timeout which is set to a default value of 10800 (equals 3 hours),

with the mxglobalsettings command.

Example to retrieve the current value:

mxglobalsettings -ld Storage_DC_Timeout

Example to modify the value to 4 hours (14,400 seconds):

mxglobalsettings -s Storage_DC_Timeout=14400

It has been observed that data collection can take 3 hours and 37 minutes on an XP24000 array that has
~3200 lives, 40n network ports, and ~150 disks.
-------------------------------------------------------------

If an HP Logical Server that is created in Insight Dynamics is given the same name as the operating system
host name of the blade on which it is applied, then the logical server is deleted when the blade is rediscovered.

Solution: To avoid this, be sure the logical server name is different from the host name of the blade.

-------------------------------------------------------------
If you:

Configure an HP Serviceguard package as an HP virtual machine which is hosted by two different HP
virtual machine hosts,

AND

Complete a failover of the package from one HP virtual machine host to the other one,
AND

Re-identify the package in Systems Insight Manager,

you might find that the package is not associated with the correct HP virtual machine host.

Solution After a Serviceguard package fails over from one host to a different host, you must re-identify the
HP virtual machine host system in Systems Insight Manager to see the correct association.

-------------------------------------------------------------
Orphan systems are appearing after I run discovery.
Solution: To prevent orphans from appearing in the future, review events and remove the system that you
have migrated to a new system type before rediscovering the new system after it is booted. This is true of
systems moving in or out of a virtual system environment.
-------------------------------------------------------------
If you see the preferred system name is different than the host name of the full DNS name for an HP virtual
machine guest, it is because the preferred system name is specified in the virtual machine package.

132