Manually setting up an hp-ux managed system, Configuring snmp to send traps to the cms – HP Systems Insight Manager User Manual

Page 23

Advertising
background image

If iCap information is desired, also install:

▲

B9073BA version 08.01.01 iCAP for HP-UX

2.

Ensure the managed system software is installed.

To verify that the minimum required software is installed, log in to the remote system, and run the
following command:

$ swlist –l bundle T1471AA B8465BA OpenSSL

To verify that the optional providers and HP System Management Homepage are installed, run commands
such as:

$ swlist –l bundle LVMProvider WBEMP-LAN-00 SysMgmtWeb SysFaultMgmt

OnlineDiag

3.

Acquire and install the managed system software if not previously installed.

The SSH and WBEM bundles are included on the HP-UX Operating Environment and Application Release
media, as well as part of the Systems Insight Manager HP-UX depot downloaded from

http://h18013.www1.hp.com/products/servers/management/hpsim/dl_hpux.html

.

For the WBEM providers, see

http://h18013.www1.hp.com/products/servers/management/hpsim/dl_hpux.html

.

After you have obtained the depots containing the software, you can install then from the managed
system:

$ swinstall –s <depot_location> OpenSSL

NOTE:

B8465BA and B9073BA version 08.01.01 depends on OpenSSL, so you must install OpenSSL

first.

$ swinstall –s <depot_location> T1471AA

$ swinstall –s <depot_location> B8465BA

$ swinstall –s <depot_location> <names of WBEM providers being installed>

After you have verified that the correct management software is installed on your managed systems, continue
to Chapter 4

Credentials

> to finish the configuration from the Systems Insight Manager user interface.

Manually setting up an HP-UX managed system

Although chapters 4-7 explain how to finish configuring managed systems from the Systems Insight Manager
GUI, this section describes how to perform some of these same steps from the command line for HP-UX
systems. You do need to first supply credentials and discover the systems, as described in Chapter 4

Credentials

and Chapter 6

Discovery

. Then you can do the following actions from the command line, if

desired.

You can use the Systems Insight Manager Configure or Repair Agents tool to configure HP-UX managed
systems simultaneously, or you can configure each managed system manually.

Configuring SNMP to send traps to the CMS

•

On the managed system, add the full host name or IP address of the CMS as a trapdest in the following
file:

/etc/SnmpAgent.d/snmpd.conf

trap-dest: hostname_or_ip_address

•

Stop the SNMP Master agent and all subagents with the command:

/sbin/init.d/SnmpMaster stop

•

Restart the SNMP Master agent and all subagents with the command:

/usr/sbin/snmpd

Setting up HP-UX servers to be managed by Systems Insight Manager