HP StorageWorks 2.32 Edge Switch User Manual

Page 18

Advertising
background image

Element Manager overview

18

Using the Element Manager, you can:

•

Back up and restore configuration data.

•

Clear the system error indicator.

•

Configure Fibre Channel operating parameters for the fabric, such as R_A_TOV, E_D_TOV,

switch priority, and interop mode. You can also configure Fibre Channel operating parameters

for the switch, such as preferred and insistent domain ID, rerouting delay, and domain RSCNs.

•

Configure individual ports with a port name describing the node attached to the port.

•

Configure keys for new features.

•

Configure interoperability mode for open switch fabrics.

•

Configure Preferred Paths for interswitch links (ISLs).

•

Configure link incident (LIN) alerts.

•

Configure a nickname to display instead of the world wide name (WWN) for the switch and

attached nodes.

•

Configure Port Binding and port speed.

•

Configure SNMP trap recipients and community names.

•

Configure Switch Binding if the optional SANtegrity Binding feature is installed.

•

Configure Open Trunking if the optional Open Trunking feature is installed.

•

Configure Open Systems Management Server features if the optional Open Systems

Management Server feature is installed.

•

Configure the switch name, location, description, and contact person.

•

Control individual Fibre Channel ports by blocking/unblocking operation, enabling LIN alerts

and Port Binding, and running internal and external loopback diagnostics.

•

Display field replaceable unit (FRU) properties such as the FRU name, physical position in the

switch (chassis slot number), active/failed state, part number, and serial number.

•

Display information for individual Fibre Channel ports, such as the port name, port number,

Fibre Channel address, operational state, type of port, and login data.

•

Display information on nodes attached to ports.

•

Display port performance and statistics.

•

Display vital product data for the switch, such as the system name, description, contact person,

location, status, model number, firmware and Engineering Change (EC) level, and

manufacturer.

•

Enable beaconing for ports and the switch unit.

•

Enable Alternate Control Prohibited (ACP) to restrict access to FICON switch connectivity

parameters.

•

Monitor the operational status of the switch and each of its hardware field-replaceable units.

•

Perform an initial program load (IPL).

•

Perform maintenance tasks for the switch, including maintaining firmware levels, administering

the Call Home Notification feature, accessing the switch logs, and collecting data to support

failure analysis.

•

Reset port operation.