HP StorageWorks 2.32 Edge Switch User Manual

Page 53

Advertising
background image

Edge Switch Element Manager user guide

53

•

07 Non-HP switch at other end of the ISL

—The cable is connected to a non-HP

switch, and interop mode is set to Open Fabric 1.0 mode.

•

08 ISL connection not allowed on this port

—The port type configuration

does not match the actual port use. (The port is configured as an F_Port, but attaches to a

switch or director.)

•

10 Port binding violation - Unauthorized WWN

—The WWN entered to

configure Port Binding for this port is not valid, or a nickname was used that is not

configured for the attached device in the Element Manager.

•

11 Unresponsive node connected to port

—Possible causes are:

• Hardware problem on switch or on a connected node where ELP frames are not

delivered, the response is not received, or a fabric login (FLOGI) cannot be received.

There may be problems in the switch SBAR.

• Faulty or dirty cable connection.
• Faulty host bus adapters that do not send out FLOGI within a reasonable time frame.

•

0x0C ESA Security Mismatch

—Processing of Exchange Security Attribute Frame

detected required security feature mismatch.

•

0x0D Fabric Binding Mismatch

—Fabric Binding is enabled and detected a switch

connection with an incompatible fabric membership list. Could also be the result of

problems delivering EFMD ILS.

•

0x0E Authorization Failure Reject

—The switch on the other side of the ISL

detected a security violation. This switch receives notification via a generic reject reason

code and sets its port to the invalid attachment state in sympathy.

•

0x0F Unauthorized Switch Binding WWN

—A Switch Binding error was detected on

either an E_Port or F_Port.

•

0x10 Authentication Failure.

ISL Authentication Check (CHAP) failed—If you wish

to allow the connection, update the authentication lists or disable authentication.

•

0x11 Fabric Mode Mismatch

—A connection was not allowed because:

• An HP M-Series switch or director attempted to connect to an HP switch or director

running in Open Fabric mode.

• An HP M-Series switch or director running in Open Fabric mode attempted to connect to

another vendor’s switch or director with an incorrect ELP revision level.

•

0x12 CNT WAN Extension Mode Mismatch

—The ELP maximum frame sizes were

incompatible because one product running in CNT WAN extension mode attempted to

connect to another product running in a normal mode.

Segmented E_Port messages:
•

Incompatible operating parameters, such as resource allocation

time-out values (R_A_TOV) or error-detect time-out values

(E_D_TOV) are inconsistent

—See ”

Configuring operating parameters

” on page 79

for more information.

•

Duplicate domain IDs

—See ”

Configuring operating parameters

” on page 79 for more

information.

Advertising