HP StorageWorks 2.32 Edge Switch User Manual

Page 192

Advertising
background image

Information and error messages

192

The following parameters cannot
be disabled while Enterprise Fabric
Mode is active: Insistent Domain ID,
Rerouting Delay, Domain RSCNs.

You attempted to disable these
parameters in the Configure Switch
Parameters dialog box while
Enterprise Fabric Mode is enabled.

Disable Enterprise Fabric Mode through
the Enterprise Fabric Mode dialog box in
HAFM, then disable the parameters.

The link to the director is not
available.

The Ethernet connection between the
HAFM appliance and the director is
down or unavailable.

Establish and verify the network
connection.

The link to the switch is not
available.

The Ethernet connection between the
HAFM appliance and the switch is
down or unavailable.

Establish and verify the network
connection.

The IPL configuration cannot be
deleted.

Deletion of the IPL address
configuration was attempted and was
not allowed.

Cancel the operation.

The management server is busy
processing a request from another
Element Manager.

The HAFM appliance is processing a
request from another instance of an
Element Manager, and cannot
perform the requested operation.

Wait until the process is completes, then
perform the operation again.

The optical transceiver is not
installed.

Information is not available for a port
without an optical transceiver
installed.

Install an SFP optical transceiver in the
port.

The switch did not accept the
request.

The director or switch cannot perform
the requested action.

Retry the operation. If the condition
persists, contact the next level of support.

The maximum number of address
configurations has been reached.

The maximum number of saved
address configurations has been
reached.

Delete configurations no longer needed to
allow new configuration to be saved.

The switch did not respond in the
time allowed.

While waiting to perform a requested
action, the director or switch timed
out.

Retry the operation. If the condition
persists, contact the next level of support.

The switch is busy saving
maintenance information.

The director or switch cannot perform
the requested action because it is
busy saving maintenance
information.

Retry the operation later. If the condition
persists, contact the next level of support.

The switch must be offline to
change the Management Style.

The firmware is below the required
level and you attempted to change the
management style.

Select Set Online State from the
Maintenance menu and click Set Offline.
Then change the management style. Set
the director or switch back online when
finished.

Table 8

Element Manager messages (continued)

Message

Description

Action