3.

Do not modify the SNMP configuration for VC Domain level. The default SNMP
configuration for VC Domain level is Enabled with the Community String equaling Public.
This is only available through the Virtual Connect Manager Command line interface.

Fibre Channel Port Speed cannot be set to 8Gb for a HP Virtual Connect 8-Gb 20-Port Fibre
Channel Module.

Select any value other than 8Gb as the uplink configuration speed when defining a SAN
Fabric for a HP Virtual Connect 8 Gb 20 Port Fibre Channel Module.

Figure 18 Select any value other than 8Gb as uplink and downlink configuration speeds

Select any value other than 8 Gb as the downlink configuration speed when assigning a SAN
Fabric for a HP Virtual Connect 8 Gb 20-Port Fibre Channel Module.

VC Domain tasks

From the VC Domains page, you can perform the following tasks:

License an enclosure.

Create a VC Domain Group.

Add a VC Domain to a VC Domain Group.

Remove a VC Domain from a VC Domain Group.

Perform VC Domain maintenance.

Cancel VC Domain maintenance.

Resynchronize a VC Domain with a Configuration Mismatch status.

VCEM cabinet licensing

You must purchase a license for each enclosure you want to manage. For licensing information,
see the VCEM QuickSpecs at

http://www.hp.com/go/vcem

.

To enable a VC Domain license, perform one of the following procedures:

For new VC Domain Groups:
1.

Click New VC Domain Group on the VC Domains page.

Both licensed and unlicensed VC domains are displayed.

2.

Click Add Key and enter the key string.

VC Domain tasks