HP Virtual Connect Enterprise Manager Software User Manual

Page 67

Advertising
background image

Description

Setting

Default selection for the authentication method.

None

Click CHAP or CHAPM to enable the following:

CHAP or CHAPM user names and passwords

CHAP or CHAPM user name—Required if the
authentication method is CHAP or CHAPM. This is
the user name for authentication. The user name
length is a maximum of 223 characters. If the user
name contains nonalphanumeric characters, it must
be enclosed in double quotes.

CHAP or CHAPM Secret—Required if the
authentication method is CHAP or CHAPM. This is
the password for authentication and is specified as
a string or a long hexadecimal value starting with
0x. This value must be at least 96 bits (12 bytes, 24
hexadecimal digits) long and at most 16 bytes (32
hexadecimal digits) excluding separators (‘ ‘ , ‘-‘, ‘.’,
‘:’, ‘,’ ).

Initiator Network Configuration

VLAN number used by the iSCSI initiator uses for all
sent and received packets. Valid VLAN number values
are between 1 to 4094.

VLAN ID (optional)

Address used by the iSCSI initiator. This value is in
dotted-decimal format.

IP Address (required)

IP network mask used by the iSCSI initiator. This value
is in dotted-decimal format.

Netmask (required)

Default IP route used by the iSCSI initiator. This value is
in dotted-decimal format.

Gateway (optional)

8.

In the Fibre Channel SAN connections table, set the Fibre Channel SAN connections. To add
more connections in a VC Domain, click Add FC SAN Connection. You can add up to 8
connections per slice, for a maximum of 4 slices and 32 connections. If you enter the maximum
connections allowed, Add is disabled and an error message is displayed. To remove a
connection, click the X icon at the right side of the table.

9.

(Optional) In the Fibre Channel Boot Parameters table, enter the boot parameters for defined
Fibre Channel SAN connections. The default boot parameter is Use Bios. The World Wide
Part Number (WWPN) and Logical Unit Number (LUN) are required only for the primary and
secondary SAN boot.

10. (Optional) Select FCoE Connections. The server profile editor displays the default FCoE

connections based on the available number of HP VC FlexFabric10 GB/24-port modules.
New FCoE connections must be added at the end of this list and can only be removed from
the last connection to the first connection. If the maximum number of FCoE connections is
reached, an error message is displayed.

NOTE:

If there are no SAN fabrics using the HP VC FlexFabric 10 Gb/24-port module uplink

ports, the FCoE connections can be configured as unassigned.

11. (Optional) To create the bay assignment, select VC Domain, and then select an available

target server bay. Auxiliary blades are displayed in a bay range as shown in the following
figure:

Creating a server profile

67

Advertising
This manual is related to the following products: