HP Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem User Manual

Page 54

Advertising
background image

Command line 54

Item Description

->add server-port-map MyProfile:3 GreenNetwork

Uplinkset=MyUplinkset1 UnTagged=true
Adds a new server port to shared network and label it as untagged

Item Description

remove server-

port-map

Remove a server port network mapping. This command cannot be used if the
domain setting VLanTagControl is set to "Tunnel".

Syntax

remove server-port-map <ConnectionID | *> [Network=<Network

Name>]

Parameters

ConnectionID

(required)

The reference ID of an existing enet-connection associated with a profile and a
server port. The format of the ConnectionId is: <ProfileName:PortNumber>. "*" will

remove all server-port-map configurations from the domain

Network

(optional)

The name of an Ethernet network to which the mapping exists.

Examples

->remove server-port-map MyProfile:1 RedNetwork
Removes a server port network mapping

->remove server-port-map MyProfile:1 *
Removes all server port network mappings from a profile

->remove server-port-map *
Removes all the server port mappings in the domain

Item Description

set server-port-

map

Modify an existing server port network mapping. This command cannot be used if
the domain setting VLanTagControl is set to "Tunnel" or if the network is associated

with a shared uplink port set.

Syntax

set server-port-map <ConnectionID> [Network=<Network Name>]

[VLanID=<VLanID>] [UnTagged=<true|false>]

Parameters

ConnectionID

(required)

The reference ID of an existing enet-connection associated with a profile and a

server port. The format of the ConnectionId is <ProfileName:PortNumber>.

Network

(required)

The name of a valid Ethernet network to which the mapping exists

Properties

VLanID (optional) The new VLAN ID to be used for the mapping server port to network. Valid values

include 1 to 4094.

Untagged

(optional)

Enables or disables the network to handle untagged packets. Only one network in

an Ethernet network connection is allowed to handle untagged packets. The default
value is "false". If a shared uplink set is being used, then untagged network is the

same as the native network if present, but any network can also be configured to

handle untagged packets.
When changing a network untagged option from true to false, the user is required to

provide a VLanID if the global option SharedServerVLanId is set to "false".

Examples

Advertising