Snmp-trap – HP Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem User Manual

Page 56

Advertising
background image

Command line 56

Item Description

SmisEnabled

(optional)

Enables or disables SMIS. This property is valid only for VC-FC modules. The
default value is "false". Valid values include "true" or "false".

Examples

->set snmp enet ReadCommunity=mydatacenter1

[email protected] Enabled=true
Enables the SNMP agent for VC-Enet modules and supplies a community string

->set snmp fc ReadCommunity=mydatacenter2

[email protected] Enabled=true
Enables the SNMP agent for VC-FC modules

->set snmp domain Enable=true
Enables the VC domain agent

->set snmp domain [email protected]
Sets the VC Domain system contact

Item Description

show snmp

Display the SNMP configuration settings for the VC domain.

Syntax

show snmp [Type]

Parameter

Type (optional)

Indicates the type of SNMP configuration to display. If the type is not specified,
all VC SNMP configuration information is displayed. Valid values include "Enet",

"FC", and "Domain".

Examples

->show snmp Enet
Displays SNMP configuration for VC-Enet modules only

->show snmp FC
Displays SNMP configuration for VC-FC modules only

->show snmp
Displays SNMP configuration for the VC domain and modules

-> show snmp domain
Displays SNMP configuration for the VC domain

snmp-trap

Displays SNMP trap information
Supported actions: add, remove, set, show, test

Item Description

add snmp-trap

Adds a new SNMP trap destination.
Avoid using duplicate trap destinations. Setting duplicate trap destinations can
result in duplicate traps being sent to the same destination, or only one of the

trap destinations being configured.