Command line 31

Item Description

->set fc-connection MyProfile 1 Fabric=SAN_5
Changes the fabric of an FC SAN fabric connection

->set fc-connection RedProfile 2 Fabric=""
Sets a FC SAN fabric connection to "Unassigned"

->set fc-connection BlueProfile 1 Fabric=SAN_7
Changes the FC SAN fabric of an FC SAN connection

->set fc-connection BlueProfile 1 Speed=4Gb
Changes the port speed of an FC SAN connection

->set fc-connection BlueProfile 1 BootPriority=Primary

BootPort=50:06:0B:00:00:C2:62:00 BootLun=5
Changes the SAN boot priority and sets additional boot parameters

Item Description

show fc-connection

Display the FC SAN connections associated with the server profiles.

Syntax

show fc-connection <ConnectionID>

Parameter

ConnectionID

(optional)

The ID of an existing FC SAN connection. The ID format is

<ProfileName:Port>. <ProfileName:*> can be used to display all the FC SAN
connections of a profile. '*' displays all the FC SAN connections existing in

the domain.

Examples

->show fc-connection
Displays all FC SAN connections existing in the domain

->show fc-connection Profile1:*
Displays FC SAN connections of profile Profile1

->show fc-connection Profile1:1
Displays a specific FC SAN connection of profile Profile1

firmware

Display or update Virtual Connection firmware version.
Support actions: help, show, update

Item Description

show firmware

Display the current version of firmware for all interconnect modules in the domain.

Syntax

show firmware

Examples

->show firmware
Displays current version of the firmware

->show firmware *
Displays detailed listing of all firmware