Serial number (logical) settings, Configuring serial number ranges, Server profile setup – HP Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem User Manual

Page 85

Advertising
background image

Configuring the Virtual Connect domain using the CLI 85

Serial number (logical) settings

Virtual Connect Manager can be configured to use logical serial numbers and logical UUIDs with a server

profile regardless of the type of physical server. With these configuration values, software licensed with

one or both of these values can be migrated to new hardware without re-licensing.

Configuring serial number ranges

VC-defined
> set serverid Type=VC-Defined PoolId=5
Factory-Default
> set serverid Type=Factory-Default
When using the HP-defined serial number ranges, be sure that each range is used only once within the
environment.

Server Profile setup

A Virtual Connect server profile is a logical grouping of attributes related to server connectivity that can
be assigned to a server blade. With the Virtual Connect v1.10 and higher, the server profile can include

MAC address, PXE, and network connection settings for each server NIC port and WWN, SAN fabric

connection, and SAN boot parameter settings for each Fibre Channel HBA port. After being defined, the

server profile can be assigned to any server blade within the Virtual Connect domain. A Virtual Connect
domain can have a maximum of 64 Virtual Connect server profiles.
Virtual Connect provides the ability to configure PXE settings when using either VC Assigned or factory

default MAC addresses. In addition, Use BIOS is a new option for PXE, which maintains the current

settings as configured by RBSU.
Virtual Connect also provides the ability to override the Virtual Connect assigned MACs and/or WWNs

when creating a new profile.
When a server profile is assigned to a server blade, the Virtual Connect Manager securely connects to the

server blade, configures the NIC ports with the appropriate MAC addresses and PXE settings, and
configures the FC HBA ports with the appropriate WWNs and SAN boot settings. In addition, the Virtual

Connect Manager automatically connects the server blade Ethernet and Fibre Channel ports to the

specified networks and SAN fabrics. This server profile can then be re-assigned to another server blade

as needed, while maintaining the server's network and SAN identity and connectivity.
The Virtual Connect Manager can be configured so that server blades use server factory default

MACs/WWNs or Virtual-Connect-administered MACs/WWNs. These administered values override the

default MAC addresses and WWNs when a server profile is assigned to a server, and appear to pre-

boot environments and host operating system software as the hardware addresses. To use administered

MAC addresses, select a range of HP pre-defined or user-specified MAC addresses.
Be sure to review the following list of guidelines before creating and deploying server profiles:

The server blade firmware and option card firmware must be at a revision that supports Virtual
Connect profile assignment. See the HP website (

http://www.hp.com/go/bladesystemupdates

).

Before creating the first server profile, select whether to use moveable, administered MAC addresses
and WWNs or whether to use the local server blade factory default MAC addresses and WWNs.

Advertising