Virtual Connect domains 34

Trap

Category

Severity

MIB

vcFcFabricManagedStatusChanged

2

VCM Fabric Status

Corresponds to the

name of the new state

VCD-MIB

VC module status change (deprecated) —

vcModuleManagedStatusChanged

2

VC-Enet Module Status or
VC-FC Module Status

Corresponds to the
name of the new state

VCD-MIB

Profile status change (deprecated)

vcProfileManagedStatusChanged

2

VCM Profile Status

Corresponds to the

name of the new state

VCD-MIB

Physical server change (deprecated)

vcPhysicalServerManagedStatusChang

ed

2

VCM Server Status

Corresponds to the

name of the new state

VCD-MIB

vcTesttrap

VCM Domain Status

INFO

VCD-MIB

Enet IF-MIB LinkDown

VC-Enet Port Status

INFO

IF-MIB

Enet IF-MIB LInkUp

VC-Enet Port Status

NORMAL

IF-MIB

Input utilization above high-water mark

3

VC-Enet Port Threshold

WARNING

VCM-MIB

Input utilization below low-water mark

3

VC-Enet Port Threshold

NORMAL

VCM-MIB

Output utilization above high-water
mark

3

VC-Enet Port Threshold

WARNING

VCM-MIB

Output utilization below low-water
mark

3

VC-Enet Port Threshold

NORMAL

VCM-MIB

Input errors above high-water mark

3

VC-Enet Port Threshold

WARNING

VCM-MIB

Input errors below low-water mark

3

VC-Enet Port Threshold

NORMAL

VCM-MIB

Output errors above high-water mark

3

VC-Enet Port Threshold

WARNING

VCM-MIB

Output errors below low-water mark

3

VC-Enet Port Threshold

NORMAL

VCM-MIB

vcModPortBpduLoopDetected

VC-Enet Port Status

CRITICAL

VCM-MIB

vcModPortBpduLoopCleared

VC-Enet Port Status

INFO

VCM-MIB

vcModPortProtectionConditionDetected VC-Enet Port Status

CRITICAL

VCM-MIB

vcModPortProtectionConditionCleared VC-Enet Port Status

INFO

VCM-MIB

vcSwitchMemParityErrorEvent

VC-Enet Other

INFO

VCM-MIB

¹ Only supported by the HP VC 8Gb 24-Port FC module

2

For more information, see "VC Domain Managed Status Changed traps (on page

37

)."

3

The VC Module MIB has the capability to send traps when certain bandwidth and throughput utilization thresholds are

reached. The counters are sampled at a fixed interval of 30 seconds and neither sample interval nor threshold values are

configurable in this release. Thresholds are defined as follows:
— Port utilization high water mark 95%

— Port utilization low water mark 75%

— Errors high water mark 5%

— Errors low water mark 1%
For more information, see the description field in the source code for individual MIBs.

IMPORTANT:

During OA failover or other management network disruptions, VC SNMP traps

might not reach the management station.

The VC-FC module generates connUnitPortStatusChange traps based on changes to the connUnitPortStatus

element of the FA-MIB. The following table shows the mapping of connUnitPortStatusChange trap severities

to the VC Domain MIB's trap severity definitions.