Virtual Connect domains 36

WARNING—The component has a potential problem.

INFO—Operational information on the fully functioning component.

UNKNOWN—VC Manager has not yet established communication with the component.

NORMAL—The component is fully functional.

Trap severities are only supported for VC-Enet or VCM traps.

VC Module MIB traps

The following table lists traps in the VC Module MIB.

Trap name

Trap data

Description

vcModRoleChange

moduleRole

The VCM role of the module has changed.

vcModInputUtilizationUp

port identification

The input line utilization on a port has exceeded its
high-water mark for longer than 30 seconds. port is the

index of the affected port in ifTable.

vcModInputUtilizationDown port identification

The input line utilization on a port has dropped below its
low-water mark for longer than 30 seconds. port is the

index of the affected port in ifTable.

vcModOutputUtilizationUp

port identification

The output line utilization on a port has exceeded its
high-water mark for longer than 30 seconds. port is the

index of the affected port in ifTable.

vcModOutputUtilizationDown port identification

The output line utilization on a port has dropped below its
low-water mark for longer than 30 seconds. port is the

index of the affected port in ifTable.

vcModInputErrorsUp

port identification

ifInErrors

The input error count on a port has exceeded its

high-water mark for longer than the error averaging
period. port is the index of the affected port in

ifTable.

vcModInputErrorsDown

port identification

ifInErrors

The input error count on a port has dropped below its

low-water mark for longer than the error averaging
period. port is the index of the affected port in

ifTable.

vcModOutputErrorsUp

port identification
ifOutErrors

The output error count on a port has exceeded its
high-water mark for longer than the threshold averaging
period. port is the index of the affected port in

ifTable.

vcModOutputErrorsDown

port identification
ifOutErrors

The output error count on a port has dropped below its
low-water mark for longer than 30 seconds. port is the

index of the affected port in ifTable.

vcModPortBpduLoopDetected port identification

loop status

A network loop condition is detected on this port. If the
loop condition is detected on a Flex10 port, the trap data

indicates the physical port associated with the Flex10

port.
If multiple Flex10 ports on a physical port detect a loop

condition, a separate trap is sent for each occurrence of

the loop condition.