4 scf configuration, Configuring the fibre channel converter, Scf configuration – HP Integrity NonStop H-Series User Manual

Page 41: Section 4, scf configuration

Advertising
background image

9800FC (CT9800FC) Fibre Channel Converter Installation and User’s Guide— 524957-003

4 -1

4

SCF Configuration

This section has the following topics:

Configuring the Fibre Channel Converter

1. Check that the Fibre Channel converter is installed properly.

2. Save the current $SYSTEM.ZSYSCONF.CONFIG file using the SCF SAVE

command. The SAVE command is described in the SCF Reference Manual
for G-Series Releases.

3. For each Fibre Channel converter, use the SCF ADD SCSI command to add

the converter to the system configuration database.

This example adds a Fibre Channel converter named $SFROUT1:

-> ADD SCSI $SFROUT1,SENDTO STORAGE,PRIMARYLOCATION
(1,1,52),PRIMARYSAC 2,PRIMARYCPU 0,BACKUPCPU 1,SCSIID 8

In this example:

•

The name $SFROUT1 is a recommendation. You can use any device name.

•

The SENDTO STORAGE attribute specifies the subsystem in which to install
the Fibre Channel converter.

•

The PRIMARYLOCATION attribute specifies the location (group, module,
and slot) of the CRU (adapter) to which the converter is attached.

•

The PRIMARYSAC attribute is necessary when using ServerNet/DA with a
S-SAC.

•

The PRIMARYCPU attribute specifies the primary processor.

•

The BACKUPCPU attribute specifies the backup processor.

•

The SCSIID attribute shows the SCSI ID that is configured for the Fibre
Channel converter. This ID must be set to 8 for a Fibre Channel converter.

Configuring the Fibre Channel Converter

4-1

Configuring the Storage Devices

4-2

Note. The SCSI ID for a Fibre Channel converter is preconfigured to 8 and must not be
changed.

Advertising
This manual is related to the following products: