Login re-distribution – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 127

Advertising
background image

Virtual Connect fabrics 127

The following table describes the available actions in the Define SAN Fabric screen. Clicking another link in

the pull-down menu or left navigation tree causes the current edits that have not been applied to be lost.

Task

Description

Create a fabric name

Type a name in the Fabric Name field. Do not use spaces.

Add an uplink port

Select a bay and port, and then click Add. In double-dense mode, do not
select Bay 7 or Bay 8.

Set the uplink port speed

After an uplink port has been added, click the pull-down arrow in the

Configured Speed field, and then select a speed. The default value is
Auto, which auto-negotiates the speed with the FC switch to which the

ports are connected. If 8Gb is chosen for the uplink speed on an FC

module that does not support 8Gb, the value is automatically translated
to "Auto" within VCM. This allows the module to connect at the highest

supported speed.

Set the fabric type

After a FlexFabric module port has been added, click the pull-down

arrow in the Fabric Type field, and then select a fabric type. The default
value is FabricAttach, which indicates that the module is connected using

traditional SAN switches.

Delete an uplink port

Left-click an uplink port row to select it, right-click to display a menu, and

then select Delete Port, or click Delete in the Action column.

Save changes

Click Apply.

Cancel without saving changes

Click Cancel.

Login re-distribution

When creating or editing a SAN fabric using HP VC FlexFabric 10Gb/24-port Modules in a FabricAttach

fabric, select the Show Advanced Settings checkbox to select the login re-distribution:

Manual Login Re-Distribution—Default for all FC modules. You must initiate a Login Re-Distribution
request through the VC GUI or CLI interfaces. You might re-distribute logins if an uplink that was

previously down is now available, if you added an uplink to a fabric, or if the number of logins through

each available uplink has become unbalanced for any reason.

Automatic Login Re-Distribution—When selected, the VC FlexFabric module initiates Login

Re-Distribution automatically when the specified time interval expires. For more information about
setting the time interval, see "Fibre Channel Settings (Misc.) screen (on page

133

)."

Advertising