HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 159

Advertising
background image

Virtual Connect server profiles 159

7.

To modify the Fibre Channel boot parameters, select the Show Fibre Channel Boot Parameters

checkbox under the FC HBA connections. See "Fibre Channel boot parameters (on page

172

)."

After selecting an item from the pull-down menu in the Boot Setting column, you must click outside the
grid to complete the selection. This is the same procedure that is followed when selecting a fabric or

network for an FC or Ethernet connection, respectively. After the Boot Setting column has been

completed, you can edit the Target Port Name and LUN.

8.

Set up FCoE HBA connections:

o

Click on the down arrow under FC SAN Name to select an available SAN.

o

Click on the Port speed to select 1, 2, 4, 8, Custom, or Disabled. The default is 4Gb, and the Custom
option allows you to choose a value between 100Mb and 10Gb in 100Mb intervals.

9.

To modify the Fibre Channel boot parameters for booting over FCoE, select the Show Fibre Channel
Boot Parameters checkbox under the FCoE HBA connections. See "Fibre Channel boot parameters (on

page

172

)."

After selecting an item from the pull-down menu in the Boot Setting column, you must click outside the
grid to complete the selection. This is the same procedure that is followed when selecting a fabric or

network for an FC or Ethernet connection, respectively. After the Boot Setting column has been

completed, you can edit the Target Port Name and LUN.

10.

To assign the server profile to a device bay, click the down arrow next to Select Location to select an
enclosure and bay number. This step can be deferred.
If the VC domain is configured for double-dense server mode, and a profile is assigned to an empty
server bay, then a hot-plug installation of a single-dense server into that server bay results in the profile
not being activated. To recover the profile, unassign the profile, and then reassign it.
Be sure that the type of server blade in the bay, or planned for the bay, can support the configuration.
For example, not all server blades support FCoE connections.
If a server blade is present in the selected location, it must be powered off for the profile to be saved and
assigned properly.
For more information on server power requirements when assigning or removing server profiles, see
"Server profile troubleshooting (on page

245

)."

11.

Click Apply.