HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 178

Advertising
background image

Virtual Connect server profiles 178

Column name

Description

If the speed type is "Preferred", the speed of the network is the same as the

preferred speed of the network to which the connection is associated. If no

preferred speed is configured for a network, it defaults to "Auto".

If the speed type is "Custom", the user can configure any speed from 100Mb
to MAX Configured speed for the network in 100-Mb increments.*

Allocated Port Speed

Allocated bandwidth of the port. See "Bandwidth assignment (on page

146

)."

Boot Setting

Enables or disables offload or boot on the network connection. Valid values
are DISABLED, PRIMARY, (SECONDARY), and USE-BIOS. For more

information, see "Creating iSCSI connections (on page

161

)." After selecting

an option, you must click outside the grid to complete the selection. This is the
same procedure that is followed when selecting a fabric or network for an FC

or Ethernet connection, respectively. Once the Boot Setting column has been

completed, you can then edit the Target Port Name and LUN.

MAC

As of VC 3.70, the actual hardware MAC for mapped connections appears.
For unmapped connections, FACTORY-DEFAULT continues to appear. If the

profile is assigned, the MAC address assigned to the port appears. If the

profile is unassigned and the domain is set to show factory default MAC
addresses, FACTORY-DEFAULT appears. If the profile is using VC-defined

MAC addresses, the VC-defined MAC address appears. If the profile is using

hardware MAC addresses, FACTORY-DEFAULT appears.

Mapping

Server hardware mapping assignment. See "iSCSI and FCoE port
assignments (on page

144

)."

Action

Delete a connection. Connections can be removed starting with the last

connection in the list.

FC HBA Connections

Port

Relative order of the Fibre Channel port on the server receiving the profile

Connected to

Bay number of the VC-FC module to which the port is connected

FC SAN Name

Name of the SAN fabric to which the port is connected, or Unassigned

Status

Status of the Fibre Channel module

Port Speed Type

Speed of the VC-FC module port connected to the port

WWN

As of VC 3.70, the actual hardware MAC for mapped connections appears.
For unmapped connections, FACTORY-DEFAULT continues to appear. If the

profile is assigned, the WWN assigned to the port appears. If the profile is

unassigned and the domain is set to show factory default WWNs,
FACTORY-DEFAULT appears. If the profile is using VC-defined WWNs, the

VC-defined WWN appears. If the profile is using hardware WWNs,

FACTORY-DEFAULT appears.

Action

Delete a connection. Connections can be removed starting with the last
connection in the list.

FCoE HBA Connections

Port

Relative order of the FCoE port on the server receiving the profile

Connected to

Bay number of the VC module to which the port is connected

FC SAN Name

Name of the SAN fabric to which the port is connected, or Unassigned

Status

Status of the VC module

Port Speed Type

Speed of the VC module port connected to the port

Allocated Port Speed

Allocated bandwidth of the port. See "Bandwidth assignment (on page

146

)."

WWN

As of VC 3.70, the actual hardware MAC for mapped connections appears.

Advertising