Multiple enclosure guidelines – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 57

Advertising
background image

HP BladeSystem c-Class enclosures 57

connectivity can disable configuration attempts until the connectivity is re-established and synchronized with

the domain. The Onboard Administrator IP addresses used must be configured to be static. The Onboard
Administrator user credential for all enclosures must be consistent to enable VCSU firmware updates for VC

modules in the remote enclosures. All FC-capable modules in the same horizontally adjacent bay pair (bays

1-2, 3-4, and so on) must be of the same type and position in all enclosures.
Multi-enclosure double-dense domains require similar and compatible VC-FC modules in bays 5, 6, 7, and
8 in all enclosures if FC connectivity is required. If a multi-enclosure double-dense configuration contains

incompatible VC-FC modules in bays 5, 6, 7, or 8 in the local or remote enclosures, some or all of the

compatible VC-FC modules in the remote enclosures might be designated INCOMPATIBLE after import.

Multiple enclosure guidelines

Observe the following guidelines when connecting multiple enclosures:

Each enclosure must have at least one supported VC-Enet, Flex-10, or FlexFabric module installed.

All VC-Enet, Flex-10, or FlexFabric modules must be interconnected (redundantly stacked).

All enclosures must have the same FC and FlexFabric module configuration. For example, if bays 1 and
2 of the Primary Enclosure contain FlexFabric modules, then bays 1 and 2 of Remote Enclosures 1, 2,

and 3 must also contain FlexFabric modules.

All enclosures must have the same HP VC Flex-10/10D module configuration. For example, if bays 1

and 2 of the Primary Enclosure contain HP VC Flex-10/10D modules, then bays 1 and 2 of Remote

Enclosures 1, 2, and 3 must also contain HP VC Flex-10/10D modules.

A single domain supports up to four c7000 enclosures.

When using multiple c7000 enclosures, the number of modules supported across the enclosures within
a domain is limited. A total of 16 Ethernet and 16 VC-FC type modules can be installed. A FlexFabric

module counts as 1 Ethernet and 1 VC-FC module. Thus, up to 16 FlexFabric Modules or combinations
of FlexFabric, VC-Enet, and VC-FC modules are allowed as long as the 16-module limit for each module

type (Ethernet and FC) is not exceeded in the domain.

All Onboard Administrators and VC modules must be on the same lightly loaded and highly reliable
management Ethernet network and IP subnet.

VC modules must be running VC v3.30 or higher.

The VC-FC and FlexFabric FC-configured uplink port configuration must be identical across all
enclosures.

The Onboard Administrator firmware must be version 3.32 or higher.

All Onboard Administrators must use the same user credentials because VCSU uses the primary

credentials for the remote enclosure.

When both Primary and Standby modules in the base enclosure are taken down for maintenance or

lose power and are no longer present in the domain, you will experience a loss of the management
capabilities in the VC domain. If network and fabric uplinks were defined on the remaining enclosures,

the servers continue to have network and storage access. Both the Primary and Standby modules in the

base enclosure must be recovered to regain management access to the VC domain.

Advertising