Virtual connect fabrics, Understanding fc fabrics, Fabricattach vc san fabrics – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 116

Advertising
background image

Virtual Connect fabrics 116

Virtual Connect fabrics

Understanding FC fabrics

Beginning with Virtual Connect 3.70, there are two supported VC SAN fabric types, FabricAttach fabrics
and DirectAttach fabrics. A FabricAttach fabric uses the traditional method of connecting VC-FC and VC

FlexFabric modules, which requires an upstream NPIV-enabled SAN switch. A DirectAttach fabric reduces

storage networking costs and removes the complexity of FC switch management by enabling you to directly

connect a VC FlexFabric module to a supported HP 3PAR Storage System (HP 3PAR P10000 V400/800,
T400/800, or F200/400).
A VC SAN fabric can only contain uplink ports of one type, either attached to an external SAN switch or

directly connected to a supported storage device. VC isolates ports that do not match the specified fabric

type. The isolated port causes the VC SAN fabric status to become Degraded, as well as all associated server

profiles and the overall VC domain status.

FabricAttach VC SAN fabrics

The VC-FC and FlexFabric modules enable the c-Class administrator to reduce FC cabling by using N_Port_ID
virtualization (NPIV). The HP VC-FC and FlexFabric modules act as an FC connectivity aggregator, where

each NPIV-enabled N-port uplink can carry the FC traffic for multiple HBAs or FlexFabric adapters.
Because the uplink ports for VC-FC and FlexFabric modules are N-ports, the modules can be connected to

any data center Brocade, McData, Cisco, and Qlogic FC switch that supports the NPIV protocol. When the

server blade HBAs or FlexFabric adapters log in to the fabric through the VC-FC or FlexFabric modules, the
adapter WWN is visible to the FC switch name server and can be managed as if it was connected directly.

IMPORTANT:

The VC-FC modules and FlexFabric FC-capable ports must be connected to a data

center Fibre Channel switch that supports NPIV. Most switches support NPIV by default and no

additional configuration is necessary. See the switch firmware documentation for information to

determine whether a specific switch supports NPIV and for instructions on enabling this support.

The VC-FC and FlexFabric modules have either four or eight uplinks. Each uplink is independent of the other
uplinks and can use NPIV to aggregate up to 255 N-port connections into a single N-port uplink. If NPIV

capability of a SAN fabric switch port is lost, the disabled uplink port of the VC-FC or FlexFabric module

remains disabled until the NPIV capability is restored. HP requires connectivity to NPIV-enabled switches for

all VC-FC modules and FlexFabric FC uplink ports.
You can group multiple VC-FC or FlexFabric module uplinks logically into a Virtual Connect SAN fabric when

the uplinks are attached to the same Fibre Channel SAN fabric. You can also create multiple Virtual Connect

fabrics on the same VC-FC or FlexFabric module, and each of these fabrics can connect to a different

physical SAN fabric. You can connect to up to four SAN fabrics to a single 20-port VC-FC module or
FlexFabric module, and up to eight SAN fabrics to a single 24-port VC-FC module. When creating

FabricAttach VC SAN fabrics, consider the following:

By default, all of the VC-FC module uplinks are grouped into a single fabric, distributing connectivity
from all server blades in the enclosure.

Advertising