Directattach vc san fabrics – HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 119

Advertising
background image

Virtual Connect fabrics 119

The VC-FC and FlexFabric modules use dynamic login distribution to provide an uplink port failover

path that enables server connections to fail over within the VC SAN fabric. If a VC SAN fabric uplink

port becomes unavailable, servers logged in through that uplink are automatically reconnected using
one of the remaining uplinks in the VC SAN fabric, resulting in automatic failover.

When a previously failed uplink is reconnected to the fabric, no server logins on the VC-FC modules are
moved to the newly available port. This can cause an unbalanced situation where some uplink ports

have more server logins than others. When enabled for VC FlexFabric modules, Automatic Login

Re-distribution allows server logins to be automatically redistributed to the newly available uplink ports

to avoid an unbalanced situation. In addition, VCM enables you to manually re-distribute server logins
at any time using the GUI or the CLI. For more information, see "Login re-distribution (on page

127

)."

DirectAttach VC SAN fabrics

Virtual Connect Direct-Attach Fibre Channel for 3PAR Storage Systems transforms the efficiency of server and
storage connectivity by eliminating the need for complex, multi-tier SANs.
DirectAttach fabrics require HP VC FlexFabric modules and are supported only with 3PAR Storage Systems

(V400/800, T400/800, or F400/200). When the uplink ports of a FlexFabric module are configured for a

DirectAttach fabric, the uplink ports employ simplified SAN fabric services combined with auto-configured
initiator-based zoning. This allows the supported storage systems to be directly attached to the uplink ports

on a module without the need for an intermediate SAN fabric. The servers and the supported storage devices

log in to the VC SAN fabric independently. As a result, when powered on, the servers are always logged in

to the FlexFabric module, even if the target storage device is not yet logged in or is already logged out. This
can be seen on the Server Ports tab of the Interconnect Bay Summary screen and is in contrast to the